Basic Info.

Model NO.
AM-10F
Type
Micrometer
Material
Stainless Steel
Measurement Object
Outside Diameter
Range
0~500mm
Resolution
0.0001mm
Precision
0.0001mm
Measure Method
Manual
Accuracy
A
Precision Measuring Device
Precision Measuring Device
Certification
GB, CE
Customized
Customized
Application
Engine Block Piston Shell
Transport Package
Wooden Box
Origin
Dongguan
Production Capacity
40000 Kilogram/Kilograms Per Month

Product Description

Air Micrometer Electronic Micrometer

Air Micrometer Electronic Micrometer

Highly precise parts presently used in every aspect of the industry including consumer electronics, audio & visual devices, automotive, and communication devices are becoming more and more microscopic every year. As the precision of industrial parts advances, a simple structure measuring instruments that anybody can use to measure with high precision and few errors are required.

1.The answers to these needs are the Air Micrometer and the Electronic Micrometer.
2.The Air Micrometer is a relative measuring instrument that can measure the dimensions of a piece of work using airflow.
3.There are different measuring systems including the Flow type, and the Back Pressure type(differential pressure type).
4.Let us explain the Flow type measuring method
5.After clean air is produced with a compressor and filtered, it is blown out the nozzle with its pressure kept constant by a regulator.
6.When the clearance between the nozzle and the work to be measured changes, the amount of air being blown out of the nozzle also changes, causing the height of a float to change.
7.The movement in the position of the float can determine the actual dimensions of the piece of work.
8.There is an Electronic Micrometer similar to the above-mentioned relative measuring instrument.
9.It measures dimensions with a contracting type gauge head(detector).
This system that electrically magnifies the mechanical and very little variation enables precise measurement with prompt response, differing from an Air Micrometer.

As seen so far, our many years of precision gauge manufacturing techniques are applied in the manufacturing of measuring heads and master gauges that make full use of the characteristics regardless of being an air or Electronic Micrometer.
This precision is highly appraised and has attainted positive results in quality control and in greater efficiency in various industrial fields with Outstanding reliability

 

 

Item

 Air Micrometer

Detection method

SemiA/E conversion system

Display

Three-color LED display, 101-dot, bar graph

Digital display (displays mode, measurements and parameters)

 Function

Measurement and parameter ranking assessments: +NG, OK1-30 and +NG

Operating display function

Comes standard with 10 basic operational modes for single-channel specs

Measurement function

Inner diameter, Outer diameter, thickness, highness, straightness.

Accommodates memory capture measurements and continuous capture measurements in addition to regular measurements.

Output interface

RS-485

Air pressure supplied

300~700kPa

Power

100~240V±10% 50/60Hz 11VA

Weight (Kg)

2.8

Dimension

77mm(W)*500mm(H)*125mm(D)

Optional

Audible alarm, USB, Air auto shut off, Wireless transmission, QR code with measurements

 

Items

Standard Performances

Measuring range

5µm

10µm

25µm

50µm

100µm

Display resolution

0.1µm

0.2µm

0.5µm

1.0µm

2.0µm

Max. measuring error

0.2µm

0.4µm

1.0µm

2.0µm

4.0µm

Repeatability

0.1µm

0.2µm

0.5µm

1.0µm

2.0µm

Response time

Max 1.2s

 
Blind Hole/Counterbore Plug Single Channel Air Micrometer
Blind Hole/Counterbore Plug Single Channel Air Micrometer
Blind Hole/Counterbore Plug Single Channel Air Micrometer
 
Blind Hole/Counterbore Plug Single Channel Air Micrometer
Blind Hole/Counterbore Plug Single Channel Air Micrometer



 

Blind Hole/Counterbore Plug Single Channel Air Micrometer
Blind Hole/Counterbore Plug Single Channel Air Micrometer
Blind Hole/Counterbore Plug Single Channel Air Micrometer

 

 
 

Blind Hole/Counterbore Plug Single Channel Air MicrometerBlind Hole/Counterbore Plug Single Channel Air MicrometerBlind Hole/Counterbore Plug Single Channel Air Micrometer
 

Send your message to this supplier

*From:
*To:
*Message:

Enter between 20 to 4,000 characters.

This is not what you are looking for? Post a Sourcing Request Now
Contact Supplier